Laboratories

Robou Zahran RMC est , in 1983 we have well equipped laboratory , we are testing all quality test in the laboratory for mix design independent laboratory also .

We do preliminary  test according to ASTM & BS standards casting samples 3 layers 25 blows for cylinder and 36 blows for cubes and crushing after 3.7 and 28 days .

3 days 60 % , 7 days 75 % and after 28 days 100 % get target strength . We do weekly sieve analyses monthly specific gravity and unit weight test . We use four kind of material 3/4 ", 3/8" , washed sand and silica sand . All test done after blending course and fine aggregate according to ASTM limits . We are testing cement setting time and strength also , cement sources form yamamah.

Brand Name

Model No.

Calibration Due Dtae

Calibration Date

Description

Plant

Item No.

CROTTI G.M.

1992

25 – 04 - 06

25 – 10 - 05

Cement

Plant 3

1

CROTTI G.M.

1992

25 – 04 - 06

25 – 10 - 05

Aggregate

MADDALENA

1992

25 – 04 - 06

25 – 10 - 05

Water

 

1992

25 – 04 - 06

25 – 10 - 05

Chemical

MEV/JUSTUS

1998

25 – 04 - 06

25 – 10 - 05

Cement

Plant 4

2

MEV/JUSTUS

1998

25 – 04 - 06

25 – 10 - 05

Aggregate

MEV/JUSTUS

1998

25 – 04 - 06

25 – 10 - 05

Water

 

1998

25 – 04 - 06

25 – 10 - 05

Chemical

LIEBHERR

B3.0RIM

20 – 04 - 06

20 – 10 - 05

Cement

Plant 5

3

LIEBHERR

B3.0RIM

20 – 04 - 06

20 – 10 - 05

Aggregate

LIEBHERR

B3.0RIM

20 – 04 - 06

20 – 10 - 05

Water

LIEBHERR

B3.0RIM

20 – 04 - 06

20 – 10 - 05

Chemical

E.L.E.Ltd.

H 145

12 – 04 -06

12 – 10 - 05

Compression Machine

Laboratory

4

FAIRBANKA , U.S.A.

RLWS,IQ 355

02 – 04 - 06

02 – 04 - 05

Truck Scale

Weighing Bridge

5