Robou Zahran
RMC est , in 1983 we have well equipped laboratory , we
are testing all quality test in the laboratory for mix design
independent laboratory also .
We do preliminary test according to
ASTM & BS standards casting samples 3 layers 25 blows for cylinder
and 36 blows for cubes and crushing after 3.7 and 28 days .
3 days 60 % , 7
days 75 % and after 28 days 100 % get target strength . We do weekly
sieve analyses monthly specific gravity and unit weight test . We
use four kind of material 3/4 ", 3/8" , washed sand and silica sand
. All test done after blending course and fine aggregate according
to ASTM limits . We are testing cement setting time and strength
also , cement sources form yamamah.
|
Brand Name |
Model No. |
Calibration Due Dtae |
Calibration Date |
Description |
Plant |
Item No. |
|
CROTTI G.M. |
1992 |
25 – 04 - 06 |
25 – 10 - 05 |
Cement |
Plant 3 |
1 |
|
CROTTI G.M. |
1992 |
25 – 04 - 06 |
25 – 10 - 05 |
Aggregate |
|
MADDALENA |
1992 |
25 – 04 - 06 |
25 – 10 - 05 |
Water |
|
|
1992 |
25 – 04 - 06 |
25 – 10 - 05 |
Chemical |
|
MEV/JUSTUS |
1998 |
25 – 04 - 06 |
25 – 10 - 05 |
Cement |
Plant 4 |
2 |
|
MEV/JUSTUS |
1998 |
25 – 04 - 06 |
25 – 10 - 05 |
Aggregate |
|
MEV/JUSTUS |
1998 |
25 – 04 - 06 |
25 – 10 - 05 |
Water |
|
|
1998 |
25 – 04 - 06 |
25 – 10 - 05 |
Chemical |
|
LIEBHERR |
B3.0RIM |
20 – 04 - 06 |
20 – 10 - 05 |
Cement |
Plant 5 |
3 |
|
LIEBHERR |
B3.0RIM |
20 – 04 - 06 |
20 – 10 - 05 |
Aggregate |
|
LIEBHERR |
B3.0RIM |
20 – 04 - 06 |
20 – 10 - 05 |
Water |
|
LIEBHERR |
B3.0RIM |
20 – 04 - 06 |
20 – 10 - 05 |
Chemical |
|
E.L.E.Ltd. |
H 145 |
12 – 04 -06 |
12 – 10 - 05 |
Compression Machine |
Laboratory |
4 |
|
FAIRBANKA , U.S.A. |
RLWS,IQ 355 |
02 – 04 - 06 |
02 – 04 - 05 |
Truck Scale |
Weighing Bridge |
5 |
|
 |
 |